AIMSIZER SCIENTIFIC PTE. LTD.

201-55 Effect of morphology and particle size distribution of molybdenum powder on compaction strength

Adopt three-point bending method to determine flexure strength of 4 different molybdenum powder compaction, and observe the sample’s morphology. Study the effect of particle size distribution and particle morphology of molybdenum powder on molybdenum powder compaction strength. The results show that, by adjusting the secondary reduction process, it can be effectively controlled. HMKTest HMK-22 fisher sub sieve sizer is the most commonly used special particle size meter for molybdenum powder in the international market.

HMK-22 Fisher Sub-sieve Sizer and Fisher Scientific Sub-sieve Sizer Model 95 Parts Supplier Price Manual